Circulator pump installation


















If you are just replacing a circulator and there is already one there with flanges you will want to unbolt the flange bolts. Once the flange bolts are loose you can remove all but one flange bolt to hold the pump in place. Please note that there maybe water that also pours out when you break the flange seal. The amount of water that comes out will depend on what type of line you are on.

If you are just replacing a circulator pump on a boiler it may on be a half of a gallon or so that leaks out, but if you are on a big line it could be more. Measure the pump height but be sure to take the measurement with the flanges attached.

You will now want to cut your pipe in the place that you will be adding the pump. Once you have cut your pipe plumbing the flanges using your tools and fittings. Improper tightening of the pump flange can also cause the flange to leak. If this was a new install you will make arrangements to have someone wire this for you, or you maybe able to do this yourself depending on your electrical background. There is always a bunch of other stuff you may run into, so here is some popular questions and answers:.

Answer: Yes, but keep in mind that some pumps will have a different height and you may need to re-plumb something, but this depends on brand. Apply market research to generate audience insights. Measure content performance. Develop and improve products. List of Partners vendors. Warning This is not a project for beginners: The water may be extremely hot while you're completing the work, and various scenarios may arise that make completing this project difficult for those without plumbing experience.

Featured Video. Read More. Your Privacy Rights. To change or withdraw your consent choices for TheSpruce. At any time, you can update your settings through the "EU Privacy" link at the bottom of any page. When the thermostat calls for heat in a particular building area, the thermostat switch causes the zone valve to open, to permit hot water to flow through that zone. When the zone valve is fully open, an "end switch" inside the valve tells the heating system's circulator to begin operating, causing hot water to flow through the zone.

Typically heating systems using zone valves will have two or more zone valves usually but not always located close to the heating boiler and a single circulator pump usually located on the return end of the hot water piping close to the heating boiler. Circulator relays on heating boilers - an older and by some heating service technicians, a preferred method to control the distribution of heat to individual building areas uses a individual circulator pump to force heating water through each individual heating zone piping.

This system too is usually found on hot water baseboard heating systems. Two or more circulator relay switches, one relay for each circulator pump, will be installed to turn on and off each heating water circulator if more than one heating circulator is installed. Individual low-voltage thermostats located in the living area will respond to a call for heat by switching on the circulator relay which in turns on the V circulator pump. Air exit tanks on heating boilers and circulator pump mounting location - some heating boilers use an air exit tank mounted on the hot water header above the heating boiler to combine the function of an Expansion Tank with the Air Bleeder Valve or air purge valve to rid the hydronic hot water heating system of un-wanted air.

Air in the heating system will often rise to a high loop of radiator or heating baseboard piping where it will block the flow of hot water, leading to an air-bound heating system and no heat in some or all of the heating system. The air exit tank captures and vents unwanted air from its location above the heating boiler on the boiler outlet or supply side. When an air exit tank is used instead of a simpler expansion tank at a heating boiler, the boiler manufacturer may specify that the circulator pump be mounted on the boiler outlet side to improve the function of this device.

Thanks to Wayne Hoffman , technical advisor for Raypak, a Rheem company that provides hydronic heating equipment, for this detail. National Fuel Gas Code Z Catalog XHO Reprinted Instructional Technologies Institute, Inc. Brumbaugh, ISBN v. Macmillan Publishing Co. Excellent tips on spotting problems on oil-fired heating equipment.

Tel: Email: info carsondunlop. Carson Dunlop Associates' provides extensive home inspection education and report writing material.

The text is intended as a reference guide to help building owners operate and maintain their home effectively. Field inspection worksheets are included at the back of the volume. No noise. Previous Next. Tips for selecting and installing a circulator pump in central heating system.

What is a circulator pump A circulator pump is an electric motor housed in a steel casing. Select a proper circulator pump The choice of pump power depends on the area of the room, the requirements for the temperature and the boiler power. We proceed from the averaged indicators, calculating the characteristics of the circulator pump: For 10 m of pipe length, 0.

The regulated value for the pump is indicated in the performance curve, measured in meters of water column. Head — hydraulic resistance of the system. The value is measured in meters and, as a rule, is set by the value of the highest point of the pipeline. The water flow rate is calculated according to the boiler performance. Install a circulator pump It is recommended to install a circulator pump next to the boiler, before the first branch, but on the supply or return pipeline better on return pipeline.

Installation rules in the heating system For the convenience of dismantling, ball valves must be installed on both sides of the unit. To create a barrier to filter limescale and abrasive wear particles, it is advisable to install a special filter in front of the device.

It is advisable to install an automatic or manual air valve at the top of the bypass path, which will allow accumulated oxygen to be removed from the system. Due to the fact that the installation of pumps in the heating system of different manufacturers has its own distinctive features, it is important to observe the installation direction indicated on the pump housing. The orientation of the pump rotor shaft must be strictly horizontal. Otherwise, air pockets can form, leaving the bearings without lubrication and sufficient cooling.

This will lead to rapid wear of parts and quick equipment breakdown. There is an arrow on the pump casing in the direction of which the water in the system should move.

Joints and threaded connections must be treated with sealants, and a gasket must be placed between the mating parts. Related products. HES Domestic.